Ultrasonic transducers for beauty devices

Ultrasonic transducers for beauty devices

Compare skin scrubber elements and assemblies with MHz transducer models for integration into your device. These are components for OEM equipment, with the driver, mounting and complete device design reviewed for your application.

Features & Applications

Components for beauty-device OEMs

Send the model or frequency target, mounting details, driver information and quantity you already know.

Prepare an OEM component enquiry

  1. Identify the supplied partShare the model or application and whether you need a ceramic element, housed transducer, sensor or assembly. List any driver or matching components separately.
  2. Describe the operating conditionsInclude frequency or measuring range, drive or output, mounting, working medium, temperature and duty cycle where relevant.
  3. Agree the sample evaluationConfirm the applicable interface, inspection checks, sample quantity and production demand before the quotation and sample plan are finalized.

Identify the supplied part

Share the model or application and whether you need a ceramic element, housed transducer, sensor or assembly. List any driver or matching components separately.

Describe the operating conditions

Include frequency or measuring range, drive or output, mounting, working medium, temperature and duty cycle where relevant.

Agree the sample evaluation

Confirm the applicable interface, inspection checks, sample quantity and production demand before the quotation and sample plan are finalized.

Skin Scrubber Components (25 kHz)

Compare the listed transducer elements and the HJ-2806/C assembly for your handpiece design.

HJ-2806

Frequency: 25 kHz

Capacitance: 18 nF

Configuration: 6 plates (3 per side)

HJ-2804

Frequency: 25 kHz

Capacitance: 22 nF

Configuration: 4 plates (2 per side)

HJ-2806/C

Frequency: 25 kHz

Capacitance: 18 nF

Configuration: 6 plates (complete assembly)

MHz Transducers for Beauty Devices

Review the frequency and electrical specifications for each model before checking driver and mounting compatibility.

HJ-4012/1M

Frequency: 1 MHz

Capacitance: 3350 pF

HJ-4012/3M

Frequency: 3 MHz

Capacitance: 7000 pF

HJ-4012/5M

Frequency: 5 MHz

Capacitance: 11000 pF

HJ-4036/1M

Frequency: 1 MHz

Capacitance: 2300 pF

How to Choose 1 MHz vs 3 MHz vs 5 MHz

Treat the HJ-4012 family as a variant cluster for different treatment depths. The correct choice depends on skin zone, coupling target, applicator size, and whether the device needs deep energy delivery, a balanced facial profile, or a shallow surface-focused window.

HJ-4012/1M (1 MHz)

Deeper penetration for massage, therapeutic coupling, and broader energy delivery.

Body-care tools, deeper facial massage, and OEM programs that need stronger subsurface coupling.

Use this when the applicator must push energy deeper without moving to a larger stack.

HJ-4012/3M (3 MHz)

Balanced penetration for mainstream facial rejuvenation and clinic-grade skincare devices.

General facial treatment platforms, wrinkle-reduction routines, and all-purpose aesthetic heads.

Choose this when you need the most flexible middle ground between depth and surface precision.

HJ-4012/5M (5 MHz)

Shallow energy window for fine-line work, delicate zones, and surface-layer treatments.

High-frequency beauty heads for superficial tightening, precision anti-aging, and sensitive facial areas.

Use this when tighter thermal control and surface-focused treatment matter more than deeper reach.

  • HJ-4012/1M (1 MHz)Deeper penetration for massage, therapeutic coupling, and broader energy delivery.Body-care tools, deeper facial massage, and OEM programs that need stronger subsurface coupling.Use this when the applicator must push energy deeper without moving to a larger stack.
  • HJ-4012/3M (3 MHz)Balanced penetration for mainstream facial rejuvenation and clinic-grade skincare devices.General facial treatment platforms, wrinkle-reduction routines, and all-purpose aesthetic heads.Choose this when you need the most flexible middle ground between depth and surface precision.
  • HJ-4012/5M (5 MHz)Shallow energy window for fine-line work, delicate zones, and surface-layer treatments.High-frequency beauty heads for superficial tightening, precision anti-aging, and sensitive facial areas.Use this when tighter thermal control and surface-focused treatment matter more than deeper reach.

Beauty Application Guides

These guides give the beauty cluster a stronger editorial center. Use them when you need to explain transducer behavior, material choice, and skincare-device architecture alongside the product variants.

Why Choose YJ Piezo Beauty Transducers

YJ Piezo's transducers are engineered for the demanding requirements of beauty and medical applications

Wide Frequency Range

From 25 kHz skin scrubbers to 5 MHz precision treatments, optimized for each application

OEM Customization

Custom specifications, complete assemblies, and ready-to-integrate solutions available

Quality Assurance

Consistent performance, reliable capacitance stability, and long operational lifespan

Inside ceramic production

From prepared powder to a piezoelectric element

See the main stages of pressing, sintering, grinding, electrode application, poling and inspection, illustrated with selected photographs from ceramic processing.

YJ Piezo Beauty Transducer Applications

YJ Piezo beauty transducers power innovative devices across the cosmetic and medical sectors worldwide

OEM Notes: Integrating Transducers Into Beauty Devices

Beauty-device programs succeed or stall on integration details rather than on the ceramic itself. The transducer must bond reliably to the handpiece head, survive the adhesive and reflow choices of your assembly line, and deliver consistent output across production batches — so an OEM enquiry should include the head material, the intended bonding process, and the drive waveform of your electronics alongside the target frequency.

Wire exit and sealing deserve equal attention: skin-contact products are cleaned by end users, which makes ingress protection at the wire exit a durability item, not a cosmetic one. YJ Piezo supplies assembly-ready elements with specified lead wires, and the supporting manufacturing process can hold agreed output consistency windows agreed at the sample stage across volume production.

If your device family spans multiple treatment heads, plan the transducer variants together — shared mounting dimensions across frequencies simplify tooling and let one driver board serve the family. Send the mechanical stack-up of your current handpiece and we will flag the integration risks before quoting.

Ready to Enhance Your Beauty Devices?

Contact our team to discuss your specific requirements and receive expert guidance on the best transducer solution

Ultrasonic transducer supply